Review




Structured Review

Partec cyflow sl (scc + cd4)
Operating characteristics of flow cytometric methods for <t> CD4+ </t> T-cell enumeration, using conventional flow cytometers.
Cyflow Sl (Scc + Cd4), supplied by Partec, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cyflow+sl+(scc+++cd4)/cyflow+sl++scc+++cd4+/pmc04366094-99-14-13
Average 90 stars, based on 1 article reviews
cyflow sl (scc + cd4) - by Bioz Stars, 2026-09
90/100 stars

Images

1) Product Images from "CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy"

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy

Journal: PLoS ONE

doi: 10.1371/journal.pone.0115019

Operating characteristics of flow cytometric methods for  CD4+  T-cell enumeration, using conventional flow cytometers.
Figure Legend Snippet: Operating characteristics of flow cytometric methods for CD4+ T-cell enumeration, using conventional flow cytometers.

Techniques Used: Cytometry, Flow Cytometry, Cell Counting

Operating characteristics of Point of Care (POC) technologies for  CD4+  T-cell enumeration.
Figure Legend Snippet: Operating characteristics of Point of Care (POC) technologies for CD4+ T-cell enumeration.

Techniques Used: Fluorescence, Cell Counting

Characteristics of included studies.
Figure Legend Snippet: Characteristics of included studies.

Techniques Used: Flow Cytometry

Misclassification (%), using a CD4 thresholds of 350 cells/μl and 200 cells/μl.
Figure Legend Snippet: Misclassification (%), using a CD4 thresholds of 350 cells/μl and 200 cells/μl.

Techniques Used:

Operating characteristics of dedicated single platform  CD4+  T-cell enumeration systems.
Figure Legend Snippet: Operating characteristics of dedicated single platform CD4+ T-cell enumeration systems.

Techniques Used: Flow Cytometry, Staining

Operating characteristics of manual technologies for  CD4+  T-cell enumeration.
Figure Legend Snippet: Operating characteristics of manual technologies for CD4+ T-cell enumeration.

Techniques Used: Light Microscopy, Isolation, Microscopy

Operating characteristics of other commercially available technologies for  CD4+  T-cell enumeration.
Figure Legend Snippet: Operating characteristics of other commercially available technologies for CD4+ T-cell enumeration.

Techniques Used: Rotator Assay, Cell Isolation, Modification, Software

Related Articles

Cytometry:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Flow Cytometry:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Cell Counting:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Fluorescence:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Staining:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Light Microscopy:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Isolation:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Microscopy:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Rotator Assay:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Cell Isolation:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Modification:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.

Software:

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
Article Snippet: Manasa 2007 34 , Zimbabwe , National reference laboratory , DP FC , Partec CyFlow SL_3 (SCC +CD4 +CD45) (absolute CD4 and %CD4) , HIV pos , 229.



Similar Products

90
Partec cyflow sl (scc + cd4)
Operating characteristics of flow cytometric methods for <t> CD4+ </t> T-cell enumeration, using conventional flow cytometers.
Cyflow Sl (Scc + Cd4), supplied by Partec, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/cyflow+sl+(scc+++cd4)/cyflow+sl++scc+++cd4+/pmc04366094-99-14-13
Average 90 stars, based on 1 article reviews
cyflow sl (scc + cd4) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Operating characteristics of flow cytometric methods for  CD4+  T-cell enumeration, using conventional flow cytometers.

Journal: PLoS ONE

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy

doi: 10.1371/journal.pone.0115019

Figure Lengend Snippet: Operating characteristics of flow cytometric methods for CD4+ T-cell enumeration, using conventional flow cytometers.

Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Techniques: Cytometry, Flow Cytometry, Cell Counting

Operating characteristics of Point of Care (POC) technologies for  CD4+  T-cell enumeration.

Journal: PLoS ONE

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy

doi: 10.1371/journal.pone.0115019

Figure Lengend Snippet: Operating characteristics of Point of Care (POC) technologies for CD4+ T-cell enumeration.

Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Techniques: Fluorescence, Cell Counting

Characteristics of included studies.

Journal: PLoS ONE

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy

doi: 10.1371/journal.pone.0115019

Figure Lengend Snippet: Characteristics of included studies.

Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Techniques: Flow Cytometry

Misclassification (%), using a CD4 thresholds of 350 cells/μl and 200 cells/μl.

Journal: PLoS ONE

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy

doi: 10.1371/journal.pone.0115019

Figure Lengend Snippet: Misclassification (%), using a CD4 thresholds of 350 cells/μl and 200 cells/μl.

Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Techniques:

Operating characteristics of dedicated single platform  CD4+  T-cell enumeration systems.

Journal: PLoS ONE

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy

doi: 10.1371/journal.pone.0115019

Figure Lengend Snippet: Operating characteristics of dedicated single platform CD4+ T-cell enumeration systems.

Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Techniques: Flow Cytometry, Staining

Operating characteristics of manual technologies for  CD4+  T-cell enumeration.

Journal: PLoS ONE

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy

doi: 10.1371/journal.pone.0115019

Figure Lengend Snippet: Operating characteristics of manual technologies for CD4+ T-cell enumeration.

Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Techniques: Light Microscopy, Isolation, Microscopy

Operating characteristics of other commercially available technologies for  CD4+  T-cell enumeration.

Journal: PLoS ONE

Article Title: CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy

doi: 10.1371/journal.pone.0115019

Figure Lengend Snippet: Operating characteristics of other commercially available technologies for CD4+ T-cell enumeration.

Article Snippet: Cassens 2004 30 , Africa and Asia , ‘Hospital laboratories’ , Various , Partec CyFlow SL (SCC + CD4), NLNW , HIV pos and neg , 434.

Techniques: Rotator Assay, Cell Isolation, Modification, Software